First, H664Y extraction check valve purposes
The
 extraction check valve is mainly used for steam turbine power plant 
steam extraction system to prevent the media or water back to the 
turbine pumps and other important facilities play a protective role, the
 performance requirements for the pipeline medium Back flow, power 
outages, accidents and other abnormal state, the valve instantly shut 
down, close time is less than 0.5 seconds.
  Second, H664Y pumping check valve performance specifications
  1, the nominal pressure:
| Nominal pressure | 1.0 ~ 2.5 | 4.0 ~ 6.4 | 10.0 | 
| Nominal diameter | 50 ~ 1000 | 50 ~ 400 | 80 ~ 350 | 
2, the medium: water, steam, air, oil 
3, the working temperature: 
| The main material | WCB | WC6 | WC9 | 
| Operating temperature | ≤425 ℃ | ≤540 ℃ | ≤550 ℃ | 
Third, H664Y suction check valve main dimensions
| H664H-10 | ||||||||||
| DN | L | D | D1 | D2 | H | H1 | H2 | H3 | L1 | W (kg) | 
| 450 | 740 | 428 | 476 | 630 | 990 | 425 | 510 | 755 | 486 | 620 | 
| 500 | 790 | 468 | 520 | 658 | 990 | 470 | 545 | 852 | 554 | 759 | 
| 700 | 1040 | 682 | 747 | 845 | 990 | 560 | 625 | 1240 | 820 | 1258 | 
| 800 | 1295 | 780 | 842 | 995 | 1257 | 650 | 645 | 1348.3 | 928 | 1788 | 
| 1000 | 1600 | 1110 | 1150 | 1230 | 1700 | 850 | 745 | 1840 | 1040 | 4800 | 
| H664H-16 | ||||||||
| DN | L | D | D1 | D2 | H | H1 | H2 | W (kg) | 
| 200 | 526 | 195 | 239 | 410 | 815 | 325 | 390 | 236 | 
| 300 | 610 | 300 | 354 | 494 | 845 | 350 | 445 | 376 | 
| 400 | 838 | 380 | 436 | 600 | 1142 | 450 | 490 | 674 | 
| H664H-25 | ||||||||
| DN | L | D | D1 | D2 | H | H1 | H2 | W (kg) | 
| 250 | 680 | 250 | 302 | 475 | 904 | 380 | 440 | 385 | 
| 500 | 1020 | 480 | 584 | 820 | 1240 | 580 | 560 | 1537 |